3004 Color Coated Aluminum Coil Sheet Strip
| Alloy | 3004 |
| Temper | O, H12, H14, H16, H24 |
| Width | As per request |
| Thickness | As per request |
| Port of Loading | Qingdao/Shanghai |
| Price | Chat With Us |
| Alloy | 3004 |
| Temper | O, H12, H14, H16, H24 |
| Width | 600‑1500 MM |
| Thickness | 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1.0 1.2 1.5 |
| Coating | PE Polyester / PVDF Fluorocarbon |
| Port of Loading | Qingdao/Shanghai/Tianjin |
| Price | Chat With Us |
Why 3004 Color‑Coated Aluminum Coil Is The High‑Strength Anti‑Rust Aluminum Stock
3004 color‑coated aluminum coil is produced using AA3004 aluminum‑manganese alloy substrate. After cleaning, chemical conversion pretreatment, continuous roller coating and high-temperature curing, it is finished with organic PE or PVDF paint. Compared to 3003 alloy, 3004 delivers higher tensile and yield strength while retaining good formability and excellent atmospheric corrosion resistance. The organic coating protects the aluminum substrate from UV radiation, rain, dust and mild chemical vapors. It is widely used for building roofing, wall cladding, gutter systems, industrial equipment housings, signage and light tank cladding, suitable for indoor, outdoor and light coastal working environments.
3004 sits between standard 3003 and high-performance 5052 marine alloy. It is selected when projects demand higher stiffness and dent resistance than 3003. For heavy offshore continuous salt spray environments, upgrade to 5052 color coated aluminum with PVDF coating.
Core Benefits of Using 3004 Color‑Coated Aluminum Coil Sheet Strip
- AA3004 Al-Mn alloy provides superior anti-rust performance and higher mechanical strength than 3003 aluminum
- Higher rigidity and dent resistance, less deformation under wind load for exposed outdoor building components
- Good formability for roll forming, bending and moderate stamping, compatible with standard metal processing machines
- Wide range of customizable colors: full RAL color system, metallic, matte, gloss, wood grain and stone grain texture finishes
- PE polyester coating for cost-effective indoor and mild outdoor applications; PVDF fluorocarbon coating for long-term outdoor UV and fade resistance
- Lightweight compared with coated steel, reduces static load requirements for building support structures
- Reliable coating adhesion; paint layer resists chipping during normal fabrication with proper processing parameters
- Smooth uniform surface; optional protective PE film to prevent scratches during slitting, fabrication and shipment
- Back-side anti-corrosion paint as standard, prevents substrate corrosion from coil inner surface
- Great cost-performance for outdoor roofing, industrial cladding and medium-load decorative projects
Important note: Although 3004 is stronger and more corrosion-resistant than 3003, projects with continuous heavy salt spray exposure still require PVDF top coating, or switching to 5052 marine grade aluminum substrate.
Key Mechanical & Physical Properties of 3004 Color‑Coated Aluminum
Coating does not change the mechanical performance of aluminum substrate; all properties come from AA3004 base alloy. Common available tempers: O soft, H12, H14, H16 and H24 cold-worked tempers.
| Property | 3004‑O | 3004‑H12 | 3004‑H14 | 3004‑H16 | 3004‑H24 |
|---|---|---|---|---|---|
| Tensile Strength | 110‑150 MPa | 150‑195 MPa | 170‑215 MPa | 190‑230 MPa | 160‑200 MPa |
| Yield Strength | ≤60 MPa | 120‑155 MPa | 140‑180 MPa | 170‑205 MPa | 130‑160 MPa |
| Density | 2.72 g/cm³ | 2.72 g/cm³ | 2.72 g/cm³ | 2.72 g/cm³ | 2.72 g/cm³ |
| Elastic Modulus | ~70 GPa | ~70 GPa | ~70 GPa | ~70 GPa | ~70 GPa |
| Elongation at Break | 18‑24 % | 7‑11 % | 5‑9 % | 3‑7 % | 3‑5 % |
| Thermal Expansion Coefficient | ~23.2 µm/m·°C | ~23.2 µm/m·°C | ~23.2 µm/m·°C | ~23.2 µm/m·°C | ~23.2 µm/m·°C |
Important note:
- 3004‑O temper: Maximum ductility for deep drawing and complex bending, low rigidity; mostly used for deep drawn decorative components.
- 3004‑H14 temper: Most popular general-purpose temper, balances rigidity and bending performance for roofing, wall panels, gutter and signage.
- 3004‑H16 temper: Higher hardness and dent resistance for outdoor panels under higher wind load, requires larger minimum bend radius.
- 3004‑H24 temper: Maximum hardness for flat panels, not suitable for tight-radius bending, high risk of paint cracking when over-bent.
Coating Performance Reference
| Coating Type | Typical Dry Film Thickness | Service Life Expectation | Recommended Application |
|---|---|---|---|
| PE Polyester | Top:18‑22 μm; Back:6‑10 μm | 3‑8 years | Indoor, sheltered outdoor, general decoration |
| PVDF Fluorocarbon (2‑coat) | Top:25‑28 μm; Back:6‑10 μm | 12‑20 years | Open outdoor, facade, near‑coastal proximity projects |
Corrosion Resistance
AA3004 Al-Mn substrate has better inherent corrosion resistance than pure 1060 aluminum and slightly improved compared with 3003. The organic coating acts as primary barrier protection against moisture and UV. PE polyester works well for inland and sheltered environments. PVDF fluorocarbon coating is required for open coastal, high UV and lightly polluted industrial areas to resist salt mist and color fading. If paint film gets scratched, bare aluminum will expose and may develop local pitting corrosion, touch-up paint should be applied on site.
Fabricability & Field‑Processing Guidance
3004 color‑coated aluminum can be processed with standard slitter, brake bender, roll‑former and stamping equipment.
- O temper supports tight‑radius bending and deep drawing;
- H14 is preferred for most roll‑formed building components;
- H16 delivers higher hardness with enlarged minimum bend radii;
- H24 requires larger minimum bend radii; avoid over‑bending which will cause paint cracking at bend lines.
Risk reminders: dull slitter blades create burrs and micro‑tears at edges, potential starting points for corrosion. Avoid sharp impact on coated surfaces; use protective PE film during handling. Do not weld directly on large coated surfaces without local paint removal.
Surface‑Treatment & Coating Options
- PE Polyester Coating: Cost‑effective mainstream option, rich colour selection, for indoor and mild outdoor applications.
- PVDF Fluorocarbon Coating: Premium high‑weather‑resistance coating for exterior architectural projects; excellent anti‑fading, anti‑chalking performance.
- Custom special effect finish: Metallic colour, matte/gloss adjustment, wood‑grain transfer printing, stone‑pattern finish.
- Protective PE film: Optional surface film to prevent scratching during fabrication and installation; must be peeled off after construction completion.
- Back‑side protective paint: Standard anti‑corrosion back coating for coil inner‑side protection.
Coil vs. Sheet vs. Strip / Slit‑Coil & Comparison With Alternative Alloy
Mill Terminology
- Color‑Coated Master Coil: Wide original production roll, for further slitting or customer on‑site processing. Common base widths:1000 mm,1220 mm,1250 mm,1500 mm.
- Slit Coil / Strip: Master coil pre‑slit into custom narrow fixed widths for gutters, trim parts, flashing and narrow profile production.
- Flat Sheet: Cut‑to‑length blanks, suitable for small‑batch flat‑panel fabrication, less economical for large‑volume continuous processing.
Practical purchasing tip: Specify alloy, temper, thickness, width, coating grade (PE/PVDF), RAL colour code, film requirement when placing orders.
Alloy Comparison
3004 Color‑Coated vs. 3003 Color‑Coated
| Item | 3004 Color‑Coated Aluminum | 3003 Color‑Coated Aluminum |
|---|---|---|
| Base Material | Al‑Mn alloy, higher manganese content | Al‑Mn anti‑rust alloy |
| Formability | Good for roll‑form & moderate stamping | Very good, easier forming |
| Dent Resistance | Higher stiffness & dent resistance | Moderate good stiffness |
| Salt‑Spray Performance | Better substrate strength, good corrosion resistance | Good anti-rust performance |
| Relative Mill Cost | Slight premium over 3003 | Lower baseline |
| Best Fit | High wind-load roofing, tank cladding, outdoor panels | General roofing, gutter, normal exterior decoration |
3004‑H14 vs. 5052‑H32 Color‑Coated
| Item | 3004‑H14 Color‑Coated | 5052‑H32 Color‑Coated |
|---|---|---|
| Tensile Strength | ~190 MPa | ~230 MPa |
| Marine Salt‑Spray Resistance | Good for light coastal; PVDF needed for harsh environment | Excellent base‑material marine corrosion resistance |
| Cost | Mid-range economical grade | Significant price premium |
5052 is selected for harsh open marine environment projects only.
Quick Alloy‑Temper‑Coating Selection Guidance
- Indoor decoration, ceiling, interior signage → 3004‑H14 / O temper, PE coating
- Sheltered inland outdoor roofing, gutters, fascia with higher wind load → 3004‑H14, PE or entry‑level PVDF
- Open outdoor facade, high UV exposure, near‑coastal projects → 3004‑H14 with PVDF fluorocarbon coating
- High wind-load outdoor panels → choose H16 temper
- Flat panels without complex bending → choose H24 temper
- Complex deep‑drawn decorative parts → choose O temper
- Heavy‑salt‑spray offshore environment → upgrade substrate to 5052 series
Typical Applications for 3004 Color‑Coated Aluminum Coil Sheet Strip
Building Construction & Facade
- High wind-load roofing panels, wall cladding, curtain‑wall back panels, fascia boards, gutters and down‑pipe systems
- Suspended ceilings, interior partition decorative panels, column cladding for commercial buildings, shopping malls, office complexes
Signage & Advertising Industry
- Outdoor billboards, sign boards, channel letter substrates, display panels, advertising decoration backplates
Home Appliance & Indoor Decoration
- Air‑conditioner outer panels, refrigerator decorative shells, cabinet decorative panels, indoor decorative trim components
Transportation & Industrial
- Light‑duty vehicle interior trim, trailer decorative panels; chemical tank outer cladding, equipment outer casings; decorative cladding for mechanical‑equipment housings
General Fabrication
- Roll‑formed profiles, stamped decorative covers, lightweight enclosures, decorative flashing and trim parts
Exclusion note: Bare‑coating 3004 is not recommended for unprotected heavy salt‑spray offshore locations without high‑spec PVDF coating specification; consider 5052 substrate for such severe service.
Best Practices for Fabrication, Handling & Installation
Fabrication Guidelines
- Use sharp slitter and shear blades; burrs and micro‑edge damage may become corrosion starting points.
- Follow minimum bend‑radius requirements according to temper; avoid over‑bending to prevent paint cracking.
- For stamping operations, select O or H14 temper; H24 is not fit for tight‑radius deformation.
Material Storage & Handling
- Store coils/sheets indoors, elevated off concrete floors; avoid outdoor open storage to prevent water staining and coating damage.
- Protect coil edges and coated surfaces from forklift impact, strap bruising and sharp‑object scratching.
- Keep protective PE film intact during processing; remove film after installation is fully completed.
Installation Best‑Practice
- For outdoor application, ensure seam overlap and proper sealing to avoid water penetration behind panels.
- Use aluminum or 300‑series stainless‑steel fasteners only; carbon‑steel fasteners will trigger galvanic corrosion risk in humid atmosphere.
- Touch‑up any paint scratches or damage points on‑site with matched touch‑up paint.
Pre‑Order Checklist
- Confirm alloy: 3004
- Confirm temper: O / H12 / H14 / H16 / H24 (H14 is default general‑purpose)
- Confirm thickness and finished width (slit‑to‑width dimension if strip product required)
- Specify coating system: PE or PVDF; provide exact RAL colour number
- Confirm whether surface protective PE film is required
- Request Mill‑Test‑Report (MTR) verifying substrate mechanical properties and coating film‑thickness test record
- Specify export‑grade packaging requirements
Common Fabrication & Service Challenges
1. Paint cracking at bend lines
Cause: insufficient bend radius, wrong temper selection.
Solution: follow temper‑specific minimum bend radius; select softer O/H14 for forming‑heavy work.
2. Colour fading and chalking on outdoor service
Cause: using PE coating under long‑term strong UV open‑air exposure.
Solution: specify PVDF fluorocarbon coating for exterior building projects.
3. Local pitting corrosion
Cause: coating scratch damage exposing bare aluminum, or dissimilar‑metal contact.
Solution: protect surface during processing; touch‑up scratches; use compatible stainless‑steel fasteners.
4. Coating delamination / poor adhesion
Cause: improper pretreatment during manufacturing or surface contamination before painting.
Solution: require supplier’s coating‑adhesion test record (cross‑hatch test) in MTR documents.
How to Specify 3004 Color‑Coated Aluminum Coil / Sheet / Strip
Write complete specification on purchasing document, example:
Alloy 3004, Temper H14, Color‑Coated Aluminum Coil, Thickness 0.8 mm, Width 1220 mm, PVDF coating, RAL 9010 white, with protective PE film, require MTR including mechanical and coating performance report.
Avoid ambiguous description like “color aluminum coil” without temper, coating grade and colour code.
Packaging & Shipping
Standard export packaging: waterproof kraft paper + plastic protection, wooden pallets or wooden cases. Coil packing supports eye‑to‑wall or eye‑to‑sky as customer’s requirement.
FAQ
1. What is MOQ?
Generally 3 tons for standard specification; special colour / special coating will have higher MOQ, consult sales.
2. Payment terms?
TT, LC at sight are acceptable.
3. Lead‑time?
Common PE colour:10‑18 working days; PVDF fluorocarbon orders:20‑30 working days.
4. Can you supply free sample?
Small test pieces can be provided free of charge; buyer covers freight cost.
5. Can you produce slit narrow strip from master coil?
Yes, we can slit master coil to custom narrow strip width according to drawing.
Ready to Source 3004 Color‑Coated Aluminum Coil Sheet Strip?
Our 3004 color‑coated aluminum products comply with ASTM B209 and relevant coating standards, available for prototype sample and mass‑volume export orders.
Aluminum products of TMR meet the export popular
Plastic movie and brown paper can be protected at customers’ need. Also timber case or timber pallet is adopted to shield products from harm for the duration of the delivery.
There are styles of packaging, which is eye to wall or eye to sky. Customers can choose either of them for their convenience.

Why Choose TMR Aluminum
We Produce Aluminum Slug/Sheet Plate Coil/Small Roll Foil/Color Coated/Mirrored Aluminum
Rich experience
Own factory, easy control
over delivery and quality
7*24 hours
Our service runs throughout
the whole production process
Accept inspection
Third party inspection
on-site inspection
Multiple payment terms
TT, LC, DP
Get An Instant Quotation
Please fill in the form below(* are required) to send us a brief message, we will get back to you as soon as possible.