1060 Aluminum Coil for Pipe Insulation
| Alloy | 1060 AA1060 |
| Temper | H18 H14 H24 |
| Width | 1000 914 etc |
| Thickness | 0.3 0.4 0.5 0.6 0.7 0.8 1.0 |
| Port of Loading | Qingdao/Shanghai |
| Price | Chat With Us |
Why 1060 Aluminum Coil Is The Premium Pure‑Aluminum Jacketing Raw Stock for Pipe‑Insulation Systems
Many industrial steam pipelines, HVAC ductwork, chilled water lines, storage‑tank thermal‑protection assemblies start from continuous‑rolled 1060 aluminum coil before field roll‑forming, cutting, bending and installation as outer protective jacketing over mineral‑wool, glass‑wool or foam‑insulation layers. Among pure‑aluminum coil insulation‑jacketing materials, 1060 aluminum coil for pipe insulation stands as the primary wrought 1XXX‑series commercially‑pure‑aluminum roll stock for mechanical‑insulation contractors prioritizing outstanding ductility, solar reflectivity, general‑atmosphere corrosion resistance and optimized project cost.
Distinct from alloy grades such as 3003, 3105 or 5052 jacketing coil, 1060 carries minimum 99.6% aluminum content; it is non‑heat‑treatable, mechanical properties improved exclusively by cold rolling tempering. Aluminum insulation coil defines continuous mill‑produced rolled stock engineered for on‑site fabrication: cutting to strip widths, brake‑bending, circumferential wrapping around straight pipe sections, elbows, tees and vessel curvatures. It functions not as thermal‑insulation material itself, but as the weather‑resistant outer cladding that preserves underlying insulation‑layer performance.
Whether quoting building‑services HVAC insulation packages, designing general‑process‑pipe jacketing specifications, or sourcing coil stock for tank‑cladding site fabrication, understanding 1060 aluminum‑coil characteristics is essential to control field‑formability, condensation‑under‑insulation risks, UV durability, and overall installed‑system lifecycle expense.
Core Benefits of Using 1060 Aluminum Coil for Pipe‑Insulation Jacketing
1060 solid aluminum coil is the go‑to jacketing blank for general‑purpose pipe‑insulation projects for these primary advantages:
- Superior ductility for field forming; accommodates tight bending over elbows, reducers and complex pipe fittings without cracking (H14 / H16 preferred for forming; H18 provides maximum stiffness with limited bend capability)
- Good natural atmospheric corrosion resistance from self‑generating passive aluminum‑oxide surface film
- High infrared‑solar reflectivity, reducing radiative heat‑gain for hot‑service piping and minimizing solar‑heating of cold‑line insulation systems
- Lightweight (density ~2.70 g/cm³), lowering dead‑load stress on pipe hangers and support structures versus steel jacketing
- Compatible with factory‑laminated Polysurlyn moisture‑barrier backing to mitigate corrosion‑under‑insulation (CUI) risk
- Multiple available surface options: mill smooth finish, stucco‑embossed (orange‑peel) texture, corrugated profiles
- Wide mill availability in standard coil widths plus custom slit‑to‑width dimensions for project‑specific requirements
- Excellent weldability for field repair joints via TIG / MIG when needed
- Economical raw‑material pricing compared to 3003 and 5052 insulation‑jacketing alloys
- Low‑alloy‑impurity composition delivers stable surface quality for long‑term outdoor exposure under non‑marine conditions
Compared to manganese‑alloyed jacketing grades, wrought 1060 pure‑aluminum coil delivers outstanding bending performance and cost‑competitiveness, yet with moderate tensile strength and limited salt‑spray / coastal‑atmosphere durability. It fits indoor, sheltered and mild‑outdoor pipe‑insulation environments, and is not recommended for unprotected coastal or heavy‑chemical‑plant atmospheric exposure without moisture‑barrier and top‑coat paint systems.
Key Mechanical & Physical Properties of 1060 Aluminum Coil for Pipe Insulation
Most commercially supplied insulation‑jacketing‑grade coil stock is 1060‑H14, 1060‑H16, 1060‑H24 and full hard 1060‑H18 cold‑worked tempers. O‑temper fully‑soft coil exists but rarely specified for pipe jacketing due to excessive dent susceptibility in service. Mechanical values below reference baseline specification for H14 / H16 / H24 / H18, the dominant insulation‑jacketing tempers.
| Property | 1060‑H14 | 1060‑H16 | 1060‑H24 | 1060‑H18 (Full Hard) |
|---|---|---|---|---|
| Tensile Strength | 100‑125 MPa | 115‑135 MPa | 120‑140 MPa | 125‑150 MPa |
| Yield Strength | 70‑90 MPa | 85‑105 MPa | 95‑110 MPa | 100‑140 MPa |
| Density | 2.70 g/cm³ | 2.70 g/cm³ | 2.70 g/cm³ | 2.70 g/cm³ |
| Elastic Modulus | 70 GPa | 70 GPa | 70 GPa | 70 GPa |
| Elongation at Break | 10‑18 % | 8‑14 % | 7‑12 % | 3‑5 % |
| Thermal Expansion Coefficient | ~23.6 µm/m·°C | ~23.6 µm/m·°C | ~23.6 µm/m·°C | ~23.6 µm/m·°C |
| Thermal Conductivity | ~226 W/m·K | ~224 W/m·K | ~222 W/m·K | ~220 W/m·K |
Important note: 1060‑H14 delivers balanced rigidity and elongation; it is the most widely‑specified temper for general‑purpose pipe‑insulation coil. 1060‑H16 brings higher hardness and dent resistance for higher‑traffic outdoor locations at some sacrifice in minimum‑bend radius capability. 1060‑H24 offers maximum hardness for mechanical‑abuse‑prone areas but requires larger bend radii for fitting fabrication. 1060‑H18 full hard is the stiffest temper of 1060 series, best for flat cladding panels with minimal bending requirements; field bending is limited and high risk of cracking at tight radii. O‑temper soft material is reserved only for complex deep‑form fittings pre‑fabricated in‑shop, not site‑erected jacketing.
Corrosion Resistance
1060 pure‑aluminum coil forms a dense, self‑repairing oxide passivation layer upon exposure to air. It performs excellently under dry‑indoor and mild‑outdoor atmospheric service. It out‑performs carbon‑steel jacketing significantly, yet lacks manganese‑alloy corrosion enhancement seen in 3003 grade. It is vulnerable to chloride‑rich salt‑spray, concentrated alkaline conditions and persistent condensation trapped behind jacketing.
Critical mitigation: For high‑humidity cyclic‑condensation environments, specify coil factory‑bonded with Polysurlyn moisture‑barrier film on the insulation‑facing inner surface to prevent direct metal‑to‑insulation contact and corrosion‑under‑insulation. Coastal or chemical‑fume locations require paint top‑coats or alloy upgrade to 3003 / 5052 jacketing grades.
Field‑Forming & Fabricability of Insulation‑Grade Coil Stock
Solid 1060 insulation coil machines and bends readily using standard sheet‑metal‑contractor tooling: hand brakes, roll‑formers, slitters, nibblers and shear cutters. H14 temper offers the broadest fabrication window. H16 / H24 require increased minimum‑bend radii for elbows and complex fitting geometry. H18 full hard coil is only recommended for flat panel cladding; avoid bending for elbows or complex fittings, micro‑cracks will easily occur at bend lines.
Common forming risks: sharp tool edges can create micro‑cracks at bend lines for higher‑hardness tempers; thin gauges (0.3 mm and below) are susceptible to denting during transport, handling and post‑installation service. Stucco‑embossed surface texture improves panel rigidity and visually hides minor dents compared to smooth mill‑finish coil.
Surface‑Treatment Compatibility
1060 insulation‑jacketing coil supports multiple factory and field surface configurations:
- Mill smooth finish: clean metallic surface, easy‑to‑clean for indoor mechanical rooms; fingerprints and minor physical damage remain visually apparent.
- Stucco embossed (orange‑peel): dominant outdoor‑jacketing texture; embossing boosts panel stiffness, masks minor denting and reduces solar glare on large tank‑farm installations.
- Corrugated cross‑crimped: enhanced rigidity for large‑diameter tank cladding.
- Polysurlyn moisture‑barrier lamination: factory‑applied inner‑side polymer film, primary defence against CUI for chilled‑water and cyclic‑temperature piping.
- Field paint / PVDF top‑coating: applied on‑project for enhanced coastal / chemical‑fume corrosion protection.
Decorative anodizing is rarely specified for pipe‑jacketing coil; service conditions prioritize barrier‑film and paint‑system performance over cosmetic anodized finishes.
1060 Insulation Coil vs. Sheet / Strip / Slit‑Coil & vs. Alternative Alloy Jacketing Coils
Coil vs. Sheet, Strip and Slit‑Coil (Mill Terminology)
- 1060 Aluminum Insulation Coil: master wide‑width mill roll, continuous length, source material for site‑slitting or factory pre‑slitting for pipe jacketing applications. Typical base widths: 914 mm, 1000 mm, 1200 mm, 1219 mm.
- Slit Coil: master coil cut into custom narrower fixed widths matching common pipe‑jacketing panel dimensions, ready‑to‑ship for contractor use.
- Flat Sheet: discrete cut‑to‑length blanks; less‑efficient for large‑volume pipe‑jacketing versus continuous coil.
- Strip: narrow width slit product used for closure bands, trim and flashings.
Critical practical point: When purchasing “1060 aluminum coil for pipe insulation”, always specify temper, thickness, surface finish and whether Polysurlyn moisture‑barrier lamination is required. H14 temper is default for balanced forming‑versus‑rigidity performance. Select H16 only for locations with high risk of mechanical impact damage. Choose H18 only for flat panels with no complex bending work. Avoid thin‑gauge coil (<0.4 mm) for unprotected outdoor service due to dent vulnerability.
Alloy‑to‑Alloy Jacketing‑Coil Comparison
1060‑H14 Coil vs. 3003‑H14 Coil
| Property | 1060‑H14 Pipe‑Insulation Coil | 3003‑H14 Pipe‑Insulation Coil |
|---|---|---|
| Base Material | Commercially pure Al ≥99.6 % | Al‑Mn anti‑corrosion wrought alloy |
| Tensile Strength | ~110 MPa | ~145 MPa |
| Ductility / Minimum Bend | Excellent; tight‑radius fittings easily formed | Very good; slightly larger bend radii |
| Salt‑Spray / Atmospheric Corrosion | Good (mild environments only) | Significantly better; preferred coastal baseline |
| Dent Resistance | Moderate | Improved stiffness and dent resistance |
| Weldability | Excellent | Very good |
| Relative Mill Cost | Lower baseline cost | Moderate premium above 1060 |
| Best‑Fit Application | Indoor, sheltered, mild‑outdoor general‑purpose pipe insulation | Semi‑outdoor, coastal‑proximity, chemical‑plant‑adjacent jacketing |
Select 1060 insulation coil for cost‑sensitive indoor and sheltered‑outdoor mechanical‑insulation projects. Upgrade to 3003‑H14 when improved corrosion and mechanical robustness are non‑negotiable design constraints.
1060‑H14 Coil vs. 5052‑H32 Coil
| Property | 1060‑H14 Pipe‑Insulation Coil | 5052‑H32 Jacketing Coil |
|---|---|---|
| Tensile Strength | ~110 MPa | ~230 MPa |
| Salt‑Spray Corrosion | Good | Excellent (marine‑capable) |
| Formability | Outstanding | Very good |
| Raw‑Material Cost | Economical | Significant price premium |
5052 jacketing coil is specified for severe marine‑exposed insulation cladding where maximum corrosion performance is required. For most standard mechanical‑insulation projects, 1060 or 3003 deliver better cost‑performance balance.
Quick Alloy‑and‑Temper Selection Guidance for Insulation Jacketing Starting Coil
- Indoor mechanical‑room pipe insulation, sheltered outdoor, cost‑optimized → 1060‑H14 aluminum coil; add Polysurlyn moisture‑barrier for cold‑chilled‑water lines
- Semi‑outdoor, near‑coastal, moderate chemical‑fume exposure → 3003‑H14 jacketing coil
- Open marine / heavy salt‑spray environment → 5052‑series jacketing coil with protective paint top‑coats
- High mechanical‑abuse risk, flat panels only, no complex bending → 1060‑H18 full hard coil
- Higher mechanical‑abuse risk with bending still required → upgrade temper from H14 to H16; increase minimum specified thickness
Typical Applications for 1060 Aluminum Coil for Pipe‑Insulation Jacketing
Solid 1060 aluminum coil serves as starting raw roll stock for these building‑services and industrial‑insulation assemblies:
Building Services & HVAC Systems
- Hot‑water, chilled‑water, condenser‑water piping outer jacketing for hospitals, commercial malls, office‑building mechanical‑rooms
- Air‑handling duct external cladding for thermal‑ and condensation‑control
- Shelter‑roof‑mounted HVAC equipment insulation enclosure cladding under mild atmospheric conditions
General‑Process Industrial Piping
- Low‑to‑moderate‑temperature steam and condensate return lines inside plant buildings
- Non‑corrosive‑media process piping insulation protection for inland factories
- Equipment‑skid pre‑fabricated pipe‑jacketing for inland‑located process‑modules
Storage‑Tank & Vessel Insulation Cladding
- Vertical and horizontal atmospheric‑storage‑tank thermal‑insulation outer covering (sheltered / inland locations; frequently stucco‑embossed finish; H18 can be used for flat tank panels)
- Heat‑exchanger and pressure‑vessel insulation protective cladding for indoor installations
District‑Energy & Municipal Utility Pipelines
- District‑heating buried‑pipe above‑ground‑run jacketing under sheltered conditions
- Central‑utility‑plant piping insulation outer protective layer
Important exclusion note: 1060 coil is not the preferred primary selection for unprotected open‑coastal, offshore‑platform or heavy‑acid‑fume chemical‑plant jacketing applications. For those environments, specify 3003 or 5052 alloy grades.
Best Practices for Fabrication & Installation Using 1060 Aluminum Insulation Coil
1060 pure‑aluminum insulation coil is soft relative to manganese‑alloy jacketing grades. Field‑work strategy must focus on minimizing denting, controlling minimum‑bend radii, proper moisture‑barrier orientation, and correct fastener specification to avoid galvanic‑corrosion risks. Special note for H18: eliminate tight-radius bending, limit H18 usage to flat cladding panels only.
Tooling for Coil‑Fabrication
- Use sharp high‑quality shear blades and slitters; dull tooling produces burrs and micro‑tears which initiate field‑corrosion sites.
- For brake‑bending elbows and fitting segments: follow temper‑specific minimum‑inside‑bend‑radius guidelines. H14 tolerates tighter bends; increase bend radius for H16 / H24 material. Do not brake bend H18 coil for elbows or small-radius fittings.
- Avoid pointed‑nibbler tool‑damage to panel edges; damaged edges become corrosion initiation points.
Material‑Handling & Storage before Installation
- Store master and slit coils indoors, elevated off concrete floors, protected from rain and condensation. Unprotected outdoor coil storage generates surface water‑staining and early onset of superficial corrosion.
- Protect coil edges from fork‑lift and strap‑damage during receiving and job‑site movement. Edge nicks propagate during forming operations, especially critical for H18 hard temper.
Work‑Site Installation Best‑Practice
- Moisture‑barrier orientation rule: Polysurlyn‑laminated coil must always install with polymer‑film side facing inward, toward the insulation material; aluminum metallic surface faces exterior weather exposure. Reversed installation nullifies CUI‑protection function.
- Fastener selection: deploy aluminum or stainless‑steel fasteners. Do not use plain‑carbon‑steel screws / bands; mixed‑metal contact creates galvanic‑corrosion.
- Overlap design: maintain standard jacketing lap‑seam dimensions; seal seams with compatible butyl or acrylic aluminum‑jacketing sealant to block rain‑water ingress.
- Avoid excessive tightening of metal bands; over‑compression creates local denting on soft‑1060 jacketing panels, even H18 full hard grade.
- For thin‑gauge coil in high‑traffic plant‑aisle locations: select increased nominal thickness or upgrade to H16 / H18 temper for improved mechanical‑abuse resistance.
Pre‑Order & Pre‑Installation Preparation for Coil Stock
- Confirm temper specification: 1060‑H14 for most general‑purpose pipe‑insulation projects. Specify H16 only when higher dent resistance is required. Use 1060‑H18 only for flat cladding panels without bending. O‑temper is almost never used for field‑erected jacketing.
- Explicitly define surface requirement: smooth mill‑finish, stucco‑embossed, corrugated; clearly state whether Polysurlyn moisture‑barrier lamination is required.
- Confirm required thickness: common project‑specified gauges are 0.4 mm, 0.5 mm, 0.6 mm, 0.7 mm, 0.8 mm. Thin 0.3 mm is acceptable for indoor low‑abuse locations; avoid below‑0.4 mm for outdoor use.
- Select base‑coil width or specify factory pre‑slit‑to‑width dimensions matching your typical jacketing‑panel sizes.
- Inspect incoming‑coil surface condition and edge quality upon material delivery; reject coils with deep edge‑nicks, heavy scratches or water‑stained surfaces. Edge nicks are especially risky for H18 material.
- For critical‑spec industrial projects, request mill‑test‑reports (MTR) verifying alloy, temper and mechanical‑property compliance against ASTM B209 standard.
Common Fabrication & In‑Service Challenges Specific to 1060 Aluminum Pipe‑Insulation Coil Stock
1. Field Denting & Mechanical‑Abrasion Damage
1060 pure‑aluminum has moderate hardness. Coil converted to thin‑gauge jacketing panels dents easily from impact, careless handling or overtightened metal‑band clamps. H14 temper is more susceptible than H16 / H24 / H18.
Solution: Specify adequate nominal thickness; upgrade temper to H16 for high‑impact‑risk zones; select H18 for flat panels needing maximum rigidity; utilize stucco‑embossed surface texture which conceals minor cosmetic dents; enforce proper‑torque band‑installation procedures on‑site.
2. Corrosion‑Under‑Insulation (CUI) behind Jacketing
Condensation migration, rainwater seepage through imperfect seams creates trapped moisture between aluminum jacketing and porous insulation material. Without separating polymer‑film barrier, localized pitting corrosion develops on inner aluminum surface.
Solution: For cold‑service piping and cyclic‑condensation systems, order coil factory‑laminated with Polysurlyn moisture‑barrier backing; strictly maintain correct film‑inward installation orientation; properly lap and seal all longitudinal and circumferential seams with approved sealants.
3. Edge‑Tearing and Micro‑Cracking at Bend‑Lines
Dull shear / slitter tooling, or bending to radii smaller than alloy‑temper minimum limits, creates micro‑cracks at bend lines. These cracks propagate and become corrosion starting‑points in service. H18 temper is the most vulnerable to bend cracking, avoid bending entirely.
Solution: Maintain sharp fabrication‑tooling; respect published minimum‑bend‑radius values for H14, H16 and H24 tempers; avoid forcing sharp bends on higher‑hardness H16 / H24 / H18 1060 coil. H18 should only be used for flat panels.
4. Galvanic‑Corrosion Risk from Dissimilar‑Metal Contact
Contact between 1060 aluminum jacketing and uncoated carbon‑steel fasteners, bands or support hardware accelerates aluminum corrosion in humid service conditions.
Solution: Specify only aluminum or 300‑series‑stainless‑steel fasteners and securing‑bands for installation; isolate unavoidable steel‑to‑aluminum contacts with compatible non‑conductive gasketing materials.
5. Poor Durability under Unprotected Coastal‑Salt‑Spray Atmosphere
1060 pure‑aluminum lacks manganese‑alloying additions. Continuous salt‑aerosol exposure leads to progressive surface pitting if deployed without paint‑coating protection.
Solution: Avoid specifying bare 1060 jacketing for open‑coastal environments. Where 1060 must be used, apply durable field‑applied top‑coat paint systems, or switch alloy selection to 3003 / 5052 jacketing grades.
How to Select Correct Temper, Thickness, Surface Finish & Mill‑Stock Condition
Temper Selection for 1060 Pipe‑Insulation Aluminum Coil
- 1060‑H14: Cold‑worked temper with balanced ductility and panel rigidity. Recommended default temper for the vast majority of 1060‑based pipe‑insulation jacketing projects. Handles field‑bending for elbows and complex fittings well, with acceptable dent‑resistance for typical indoor and sheltered‑outdoor locations.
- 1060‑H16: Higher hardness and improved dent‑resistance. Select for plant‑aisle high‑mechanical‑abuse‑risk zones. Requires larger minimum‑bend radii during fitting fabrication.
- 1060‑H24: Maximum‑hardness commercially‑available temper for insulation coil with limited bending capability. Bend‑formability is reduced; reserved for flat‑panel cladding where forming complexity is minimal.
- 1060‑H18 (Full Hard): Highest hardness and stiffness of all 1060 tempers. Only for flat cladding panels, no field bending allowed. Ideal for tank flat panels or areas with heavy mechanical impact exposure, but not for elbows or curved pipe sections.
- 1060‑O: Fully‑annealed ultra‑soft condition. Not specified for field‑erected pipe jacketing; limited‑use only for pre‑shop deep‑drawn custom fittings.
Important: When releasing purchase‑orders, explicitly write “1060‑H14 / H16 / H24 / H18 aluminum coil for pipe insulation” together with thickness, surface finish and moisture‑barrier requirement on purchasing documents. Never rely on ambiguous generic “1060 aluminum coil” wording alone.
Thickness‑Sizing Best‑Practice
- Indoor low‑abuse mechanical‑room piping: 0.4 mm ~ 0.5 mm typical
- General‑purpose sheltered‑outdoor and plant‑interior process‑piping: 0.5 mm ~ 0.6 mm most‑common engineering‑spec range
- High‑traffic plant‑aisle locations or flat panels using H18: 0.6 mm ~ 0.8 mm for improved impact‑resistance
- Avoid gauges thinner than 0.4 mm for any outdoor application due to dent‑susceptibility.
Surface & Moisture‑Barrier Decision Points
- Smooth mill‑finish: Prefer indoor mechanical‑room installations where easy‑clean appearance is prioritized; shows fingerprints and minor physical damage clearly.
- Stucco‑embossed (orange‑peel): Default outdoor‑sheltered‑location finish; hides minor dents, increases panel stiffness, reduces solar glare.
- Polysurlyn moisture‑barrier laminated coil: Mandatory specification for chilled‑water, cryogenic‑adjacent and cyclic‑temperature piping systems, highly recommended for most outdoor‑jacketing regardless of alloy grade.
Mill‑Pricing Note
1060 aluminum‑insulation‑coil mill pricing depends on nominal thickness, coil width, temper selection, surface‑embossing requirement, Polysurlyn‑lamination add‑on, total‑order tonnage, MTR‑certification requirements and export‑packaging specifications. H16 carries moderate premium above H14; H18 full hard has an additional price uplift. Stucco‑embossed and Polysurlyn‑lamination add incremental cost versus plain smooth‑mill‑finish coil. 1060 base price sits meaningfully below 3003 and 5052 insulation‑jacketing coil grades.
Is 1060 Aluminum Coil Your Right Pipe‑Insulation Jacketing Raw‑Stock?
For insulation‑contractor and engineering‑specification projects requiring economical pure‑aluminum jacketing with excellent field‑formability for indoor and sheltered‑outdoor pipe‑and‑vessel‑insulation assemblies, 1060 aluminum coil (H14 temper preferred; specify Polysurlyn moisture‑barrier for cold‑service piping, H18 for rigid flat panels) is the proven solid rolled raw‑stock choice.
It delivers:
- Excellent ductility for on‑site brake‑bending around elbows, tees and complex pipe‑fitting geometries (H14 / H16)
- Highest rigidity and dent resistance for flat panels when selecting 1060‑H18 full hard temper
- Good general‑atmosphere corrosion performance for inland, indoor and sheltered‑outdoor service
- Multiple surface options: smooth mill‑finish, stucco‑embossed texture, optional factory‑bonded Polysurlyn moisture‑barrier for CUI mitigation
- Lightweight panel material lowering support‑system structural‑load requirements
- Good weldability for field‑repair operations
- Global mill‑supply availability in master‑coil and pre‑slit‑to‑width configurations, complying with ASTM B209 industry standards
- Competitive raw‑material cost versus manganese‑alloy alternative jacketing grades
Limitations you must engineer around:
- Moderate dent‑susceptibility for thin‑gauge panels; upgrade thickness / temper (H18) for high‑abuse‑locations
- H18 full hard temper cannot be bent for curved pipe fittings; only suitable for flat cladding
- Not suited for bare unprotected coastal salt‑spray or heavy‑chemical‑fume environments (select 3003 or 5052 instead)
- Cold‑service systems require explicit Polysurlyn moisture‑barrier specification to control corrosion‑under‑insulation risk
Unless your project demands superior salt‑spray corrosion resistance (where you would specify 3003‑H14 or 5052 jacketing coil), 1060‑H14 aluminum coil for pipe insulation, with moisture‑barrier lamination for cold‑lines and H18 for rigid flat panels, remains the primary economical rolled jacketing starting‑stock for inland and building‑services mechanical‑insulation projects.
Further Reading References
- ASM International: authoritative aluminum‑alloy metallurgical and temper specifications
- The Aluminum Association: ANSI H35.1 standard for alloy‑and‑temper designation
- ASTM B209: Standard Specification for Aluminum‑ and Aluminum‑Alloy Sheet and Plate
- ASTM C1729: Standard Specification for Aluminum‑Jacketing for Thermal‑Insulation Systems
Ready to Source 1060 Aluminum Coil for Your Next Pipe‑Insulation Project?
TMR ALUMINUM supplies precision‑produced 1060‑H14 / H16 / H24 / H18 aluminum insulation coil, available smooth‑mill‑finish, stucco‑embossed, with‑or‑without Polysurlyn moisture‑barrier lamination. We provide complete mill‑test‑reports, competitive factory‑direct pricing and flexible lead‑times for prototype‑sample through full‑project‑tonnage‑volume orders.
Aluminum products of TMR meet the export popular
Plastic movie and brown paper can be protected at customers’ need. Also timber case or timber pallet is adopted to shield products from harm for the duration of the delivery.
There are styles of packaging, which is eye to wall or eye to sky. Customers can choose either of them for their convenience.

Get An Instant Quotation
Please fill in the form below(* are required) to send us a brief message, we will get back to you as soon as possible.